CAT: BFP/VCAR
C2V04
IE/C2V04/003/2014 SHEET: 1/1
8
C2V 04 22 ** A * * 00 2
1
2
1
2
Q (l/min)
P(bar)
0
1
2
3
4
0
2
4
6810
12
Q (l/min)
P(bar)
0
50
100
150
200
250
0
2
4
6810
12
1
2
NA/NC 1 2 2 1
3/4" - 16 UNF
24
Ø12.7
Ø20
47.8
36
23.5
2
1
59 (NC)
86(NC)
66.6 (NA)
93.6 (NA)
38.5 27
()
*
()
*
2.5
Ø10
8
2 Corsa
(Stroke)
3.5 Corsa
(Stroke)
2.5 Corsa
2.5 Corsa
(Stroke)
(Stroke)
max7 Nmmax7 Nm
max7 Nm
38.2 max
29.5
30.2
Ø20
Ø21
Ø10
Ø10
Ø10
P4 E9
P3
19
13.3 (NA)
13 (NC)
SOLENOID VALVES 2 WAY 2 POSITIONS
FEATURES
HYDRAULIC SYMBOLS
Max. pressure 250 bar
Max. Flow 12 l/min
Max. excitation frequency 2 Hz
Duty cycle 100% ED
Hydraulic fluids DIN 51524 Mineral oils
Fluid viscosity 10 ÷ 500 mm²/s
Fluid temperature -25°C ÷ 75°C
Ambient temperature -25°C ÷ 60°C
Max. contamin. level class with filter ISO 4406:1999 - class 19/17/14
Type of protection
(in relation to the connection used)
IP65
Weight (with coil) 0.30 kg
Cartridge tightening torque 25 ÷ 30 Nm
Coil ring nut tightening torque 7 Nm
Cavity (3/4 - 16 UNF) CD018006 (See section 15)
Normally open Normally closed
SOLENOID VALVES - 2-WAY
Connector to be ordered separately, see sect. 18
PRESSURE DROPS LIMIT OF USE
ORDERING CODE
2 = Serial No.
Series
Coil
Voltage
Variants
C2V = Solenoid valve 3 way / 2 positions
The tests were carried out with the 22W
solenoids at operating temperature, with
a supply voltage 10% below nominal val-
ue and with a 40°C fluid temperature.
The fluid used is a mineral oil with viscosity of
46 mm²‘/s at 40°C.
Version
Flow C2V04 NA C2V04 NC
1 2 Curve 2 Curve 1
2 1 Curve 1 Curve 1
A = Ø 12.7 mm (standard)
Seat
Coils technical data, see sect. 17
DC 22W (C36)
L = 12 VDC
M = 24 VDC
N = 48 VDC
2 = 21.6 VDC RAC (2)
Z = 102 VDC RAC (3)
X = 205 VDC RAC (4)
W = Without coil (5)
The electric valve is a 2-way 2-position bidirectional electrically controlled
valve.
Slight leakage is tolerated for this type of valve.
Available in normally open (NA) or normally closed (NC) versions.
The valves work with DC coils whereas RAC coils with a connector with incor-
porated rectifier must be used for AC applications.
The sleeve is in galvanised steel (C2V0422NC..) or nickel-plated
(C2V0422NA..). The plunger is in tempered and ground steel.
00012025
Spare seals kit
22 = 22W (C36)
Size
04 = 3/4 - 16 UNF
NC = Normally closed
NA = Normally open
S = Without emergency (NC)
E = With emergency (NA - NC)
Emergency
00 = No variants
P3 = Rotary emerg.(..NA)
P4 =
Push butt. emerg.(..NA)
E9 =
Push butt. emerg.(..NA)
FK = With flying leads 600 mm (1)
AJ = AMP Junior connection (1)
Connector to be ordered separately, see sect. 18
(1) Only voltages 12 VDC - 24 VDC
(2) With rectifier: 24 VAC/50-60Hz
(3) With rectifier: 115 VAC/50Hz - 120 VAC/60Hz
(4) With rectifier: 230 VAC/50Hz - 240 VAC/60Hz
(5) Performance are guaranteed only using valves completed with BFP coil
Limits of use
Emergency (NA)
Variants
Emergency (NC)
Removable cup
Page: 78
HOME INFO VALVES INDEX